HuanRui Test teaches you how to add refrigerant to high low temperature impact boxes!

HuanRui Test teaches you how to add refrigerant to high low temperature impact boxes! The compressor is one of the core components of the high and low temperature shock box . It sucks low temperature and low pressure refrigerant gas (also called refrigerant) from the suction pipe, and after the motor is driven to drive the piston to compress it, the high temperature is discharged to the exhaust pipe. The high-pressure refrigerant liquid provides power to the refrigeration cycle to achieve a refrigeration cycle of compression→condensation→expansion→evaporation (endothermic). How to join if there is less refrigerant? 1. Prepare a scale, overweight the refrigerant cylinder and record the total net weight. 2. Place the cylinder on the scale, use a piece of x1 copper tube for one section, connect it to the cylinder with a special thread, and connect the other end to the multi-purpose channel of the high-low temperature thermal shock box compressor suction valve, and connect the mul...