Which methods can minimize the power consumption of large constant temperature and humidity chambers?

Which methods can minimize the power consumption of large constant temperature and humidity chambers?



As the industry develops more and more rapidly, the application of large-scale constant temperature and humidity test chambers is more and more extensive. Many users are responding to the process of using large-scale constant temperature and humidity test chambers, and the power consumption is large. To share with you the following effective ways can be referred to:

1. Placement: Large-scale constant temperature and humidity test chamber should be placed in a cool and ventilated place as far as possible, avoid direct sunlight, away from heat sources, and leave appropriate space on the left and right sides and back of the test box at the top of the test box to facilitate heat dissipation. . Because the ambient temperature around it will increase the power consumption of the test chamber.

2, should always check the seal of the test box seal, if the seal is deformed, it will affect the degree of closeness of the closed wire, resulting in leakage of cold air, thereby increasing power consumption. If the deformation is serious, it should be repaired and replaced in time.

3. After using the test chamber for a period of time, some frost will be generated. If it can't be tempered regularly, it will affect the cooling effect, and the power consumption will increase, and it will even damage the compressor. Therefore, whenever the thickness of the frost is seen to exceed 7 cm, defrosting should be performed.

4. Whenever you open the door, you will have cold air and heat intrusion, so you must run the compressor again. Therefore, when accessing the sample, it is necessary to minimize the number of door opening and door opening time, and to open and close the door faster, and the opening angle should be as small as possible.

5, always pay attention to the large-scale constant temperature and humidity test chamber "bath", the surface of the compressor and condenser should be cleaned every two to three months, the more dust, the worse the heat dissipation effect, the greater the power consumption, Turn off the power when cleaning, and wipe it off with a damp cloth.